4-26
When nozzle missing occurs due to ink mixture or aeration
Push out ink and air in the head from the port.
Use this when ink has been mixed in the port, or nozzle missing due to aeration occurs.
1
Select [AIR PG] of the maintenance menu.
(1)
Press the
key in LOCAL.
(2)
Press
to select [MAINTENANCE] and press the
key.
(3)
Press
to select [AIR PG].
2
Press the
key.
3
Select the subtank to air purge.
• Select the subtank with the
key
• Selectable unit is three types of “MMCC_”, “_YYKK”, and “MMCCYYKK”.
4
Press the
key.
5
Open the right maintenance cover, and set the jig
into the port.
• Remove the port corresponding to the subtank selected in
the Step 3 only. Perform this one by one.
6
Press the
key.
• When removing the jig, ink may leak. Put a
paper towel etc. around the port.
SE L ECT SUB T ANK
: MMCCYYKK
SE L ECT SUB T ANK
: MMCC _ _ _ _
PREPARE A I R PG
COMP L E T ED
[ ENT ]
Jig
Port
Jig
A I R PG
S T ART
[ ENT ]
Summary of Contents for JV400-130SUV
Page 1: ...MIMAKI ENGINEERING CO LTD URL http eng mimaki co jp D202394 17 Original instructions ...
Page 58: ...2 28 ...
Page 73: ...3 15 1 1 3 Convenient use 5 6 9 Press the key several times to end the setting ...
Page 100: ...3 42 ...
Page 162: ...5 20 ...
Page 179: ...Function Flowchart 6 17 Appendix 6 ...
Page 187: ...Function Flowchart 6 25 Appendix 6 ...
Page 192: ...6 30 ...