5-18
Message
Cause
Solution
Ink could not be supplied to the sub
tank.
• Perform “SUB TANK (
P.5-8) ” of the
maintenance. Also check the remaining
amount of ink in the cartridge.
Even if you performed this, when the
message is displayed, contact your local
distributor to call for service.
Starting of the negative pressure control
has an abnormality.
• Perform “PRESSURE ADJUST (
P.5-
9)” of the maintenance. Even if you per-
formed this, when the message is dis-
played, contact your local distributor to
call for service.
The negative pressure cannot be kept
properly
Starting of the positive pressure control
has an abnormality.
The positive pressure cannot be kept
properly.
• Perform “PRESSURE ADJUST (
P.5-
9)” of the maintenance. Even if you per-
formed this, when the message is dis-
played, contact your local distributor to
call for service.
There is a slot in which the cartridge has not been
inserted more than a certain time.
• Set a cartridge.
The thermistor of a heater is defective.
• Turn off the main power to the machine
and turn it on after a while.
If the same error message appears
again, contact your local distributor to call
for service.
A head heater is disconnected.
The UV unit is disconnected.
The UV lamp temperature is abnormal.
The UV lamp temperature is abnormal.
(High)
The UV lamp temperature is abnormal.
(Low)
The UV unit thermistor is disconnected.
The temperature abnormality of the
heater has been detected.
When this error occurred and if the tem-
perature abnormality cannot be
resolved, the power supply of the
machine is forcibly turned off.
Due to a certain error, the function can-
not be performed.
• Return to the local screen, check the
error status and take a countermeasure.
There remains received data that has
not yet been printed.
• Execute the data clear function.
(
P.2-25)
E R ROR 6 1 b
S U P P L Y I N K : 1 2 3 4 5 6 7 8
E R ROR 6 1 c
N EGA T I V E P . CON T RO L
E R ROR 6 1 d
N EGA T I V E P . N o t E n o u g h
E R ROR 6 1 e
N EGA T I V E P . OV E R
E R ROR 6 1 f
POS I T I V E P . CON T RO L
E R ROR 6 2 0
POS I T I V E P . N o t E n o u g h
E R ROR 6 2 1
POS I T I V E P . OV E R
E R ROR 6 2 7
I N S E R T C A R T R I DGE
E R ROR 7 0 2
T H E RM I S T OR
E R ROR 7 0 7
! H 1 H E A T E R B R E A K
E R ROR 7 0 c
U V UN I T B R K
E R ROR 7 0 d
U V UN I T T EMP E RROR
E R ROR 7 1 2
U V UN I T T EMP . H I GH
E R ROR 7 1 3
U V UN I T T EMP . L OW
E R ROR 7 0 e
U V T H E RM I S T OR B R K
E R ROR 7 1 0
H E A T E R T EMP E RROR
E R ROR
9 0 1
I N V A L I D OP E R A T I ON
E R ROR 9 0 2
D A T A R EMA I N
Summary of Contents for JV400-130SUV
Page 1: ...MIMAKI ENGINEERING CO LTD URL http eng mimaki co jp D202394 17 Original instructions ...
Page 58: ...2 28 ...
Page 73: ...3 15 1 1 3 Convenient use 5 6 9 Press the key several times to end the setting ...
Page 100: ...3 42 ...
Page 162: ...5 20 ...
Page 179: ...Function Flowchart 6 17 Appendix 6 ...
Page 187: ...Function Flowchart 6 25 Appendix 6 ...
Page 192: ...6 30 ...