4-25
4
2
Refill antifreeze mixed water
If an error of lack of water, refill antifreeze mixed water. To
fill up its capacity, about 200cc refill is required.
1
Made mixed water (antifreeze liquid: 1,
water: 2) in the attached reservoir and
move it to the attached syringe.
2
Uncover the feed-water inlet and the air
vent.
3
Refill antifreeze mixed water.
• Fill the antifreeze mixed water from the feed-
water inlet.
• Fill it up seeing the water gauge on the back of
this machine. Displaying red on the water gauge
indicates full.
4
Close the feed-water inlet and the air purge
cover.
• Be aware that if you put in too much antifreeze
mixed water, it may leak from the cooling water
tank.
air vent cover
feed-water inlet
Water gauge