- 5-26 -
F. Cover the illuminometer BKT 2 with match-
ing the upper left coner and positioning the
handle at upper right.
11. Press the [ENTER] key after setting the UV
illuminometer.
12. Close the left maintenance cover.
13. Select the intensity of UV level.
Pressing the [FUNCTION] key changes the
intensity of UV level. The selected intensity of UV
level is indicated at upper right of the display.
H:HIGH, N: NORMAL, L:LOW
14. Press the [ENTER] key and then the
checking is started.
• In case the check lamp lights off, it
takes time to light.
15. After checking, open the left maintenance
cover.
• When measuring the UV level, press
the [ENTER] key to back to STEP13
before opening the maintenance
cover.
16. Remove the UV illuminometer BKT 2 and
then verify the checking level on the
indicator.
• Refer to the indicator value on inside
of the UV illuminometor.
•
Do not touch the left side of the BKT 2
after checking to avoid burn injury.
PLEASE CLOSE
THE LEFT COVER
UV LEVEL CHECK
N
CHECK START
:ent
UV LEVEL CHECK
SET THE TOOL
:ent
** CHECKING **
PLEASE WAIT
PLEASE OPEN
THE LEFT COVER
UV LEVEL CHECK
N
CHECK START
:ent