- 2-9 -
before setting media
We have three ways before setting media.
• Entering head gap value ............ Enter and fix the head gap value.
• Media thickness known .............. [Sense mode] or [Continue] mode.
Media thickness unknown .......... [Media thickness] mode.
• Gap check .................................. Required when [Continue] mode is set.
Entering [Head Gap] value
The entered gap between the head and media is reflected to all media.
Enter a desired value. The registered type number is displayed. (
P.4-4)
Allowable set range: 0.9 to 2.0 mm (Initial value: 1.0 mm)
STEPS:
1.
Make sure that the LOCAL mode is dis-
played.
2.
Press the [FUNCTION] key.
3.
Select the [HEADGAP *] by pressing the
[ ] or [ ] keys
4.
Press the [ENTER] key.
This is reflected to type 1.
5.
Enter the head gap value by pressing the
[ ] or [ ] keys .
6.
The device enters to the head gap.
<<LOCAL>>
FUNCTION
HEAD GAP 1
<ent>
HEAD GAP 1
1.5mm
HEAD GAP 1
1.0mm
FUNCTION
HEAD GAP 1
<ent>
FUNCTION
DATA CLEAR
<ENT>