If the end-user is using a CE-approved motor, the correct filter
from Table 5 (page 45) is all that is necessary to meet the EMC
directives listed herein.
If the end-user is not using a CE-approved motor, a second
filter, part number CEXXMM, must be deployed on the output.
XX = rated current of the filter.
The CE20MM is a Real-Pole Balanced-Pi 3-pole filter. If the
exact filter is not available, the specifications are as follows:
L & L1 = 2 * (0.8) milliHenries.
C & C1 = 2 * (0.1) microFarads @ 400W VDC.
Rin = 0.1 ohm; Rout = 1.2 ohm.
Table 6. Minarik Filters
Nameplate Current of
Motor Wired to the Drive
Minarik Filter Part Number
0 to 4 amps
CE4MM
4.1 to 13 amps
CE20MM
The filters in Table 6 must be wired to the DC
output of the drive, as close to the drive as
possible. The ground connection from the filter
must be wired to solid earth ground (resistance
less than 500 ohms); not machine ground. This is
very important!
45
CE Compliance