3-21 Codabar
Read:
Format
Start character
Data digits (variable)
Check digit (optional) End character
Check digit verification:
The check digit is made as the sum module 16 of the numerical value of the
data digits.
Check digit trans.:
By setting Enable, check digit will be transmitted.
Max./Min. code length:
Refer to Max./Min. code length of
3-17 Code 39 (Code 32, Trioptic Code 39)
Code ID setting:
Insertion group selection:
Refer to Insertion group selection of
Start/End Type:
Codabar has four pairs of Start/End Pattern; you may select one pair to match your
application.
Start/End transmission:
Refer to Start/End transmission of
3-17 Code 39 (Code 32, Trioptic Code
Start/End character equality:
By setting Enable, the start and end character of a Codabar barcode
must be the same.
Multiple-scan setting
Single-scan setting
Option barcode
Option
Alpha. entry
Read
Disable
00
Enable
01*
*
Check digit verification
Disable
00*
*
Enable
01
Check digit trans.
Disable
00*
*
Enable
01
Max. code length
00-99
00-99
99*
*
Min. code length
00-99
00-99
04*
*
Code ID setting
00-FF
16
(ASCII)
00-FF
16
<N>*
*
Insert group selection
00-66
00-66