20
(10) Origin Search Input
When ‘Origin Search’ signal is set to ON (10ms or more), it starts to search the origin
position according to selected conditions. The conditions are subject to parameters such
as No.20:Org Method, No.17:Org Speed, No.18:Org Search Speed, No.19:Org AccDec
Time, No.21:Org Dir. (For more information, refer to ‘1.2 Parameter’.) When the origin
search command is completed, ‘Origin Search OK’ signal is set to ON.
(11) E-Stop Input
When [Emergency stop] signal is set to [ON] the current motion is stopped immediately
without deceleration. The duration of this signal must be longer than 10ms. When this
signal is activated, the servo-on procedure can’t be executed. And unlike the EMG
function, the E-STOP function can not be programmed.
Motion Pattern
po
Emergency stop input