28
5. Operation
5-1. Servo ON Operation
The default setting after power-on is Servo OFF.
The methods of “Servo ON” are as follows.
①
Click ‘Servo ON’ button at the User Program (GUI).
②
Send a command to drive through DLL library.
③
Assigned the "Servo ON" among the control input terminals and a signal is supplied
to the pin.
After Servo ON command is sent, In-position is activated as shown below.
*T1 is subject to the supplying power, motor type and parameters of drive.
5-2. Operation Mode
This controller can be controlled in two ways such as I/O command, communication
command (DLL program or User Program (GUI))
(1) Pulse Input Mode
This controller can do motions by pulse input from the upper controller
①
1 Pulse Mode : Pulse/Dir inputs
②
2 Pulse Mode : CCW/CW pulse inputs
③
Quadrature mode : A/B pulse input
The control signals such as Servo On, Alarm Reset, Servo Ready, Inposition and Alarm
signals can be set and used in pulse input mode. These control signals can be set by Plus-R
protocol without changing the operating mode.
Please do not set any other functions to I/O. Setting other functions might cause
unexpected results.
Do not set any other functions to I/O except Servo-On, Alarm
Reset, Servo Ready, Inposition and Alarm in pulse input mode.
Servo ON command
T1
Position Set
Caution