51
35
Operating mode:
Setting drive operating mode.
The change of this parameter requires
power-off/on cycle.
0 : 1 pulse mode (Pulse/Dir)
1 : 2 pulse mode (CCW/DIR)
2 : Quadrature mode (A/B)
3 : Plus-R mode
4 : MODBUS RTU mode
5 : MODBUS ASC mode
0
5
3
36
Tact Switch(SW3) Function :
0 : No function
1 : Alarm Reset
If SW3 is kept pressed when power is
on, the drive will be set to 115,200 bps
& Plus-R mode temporarily
0
1
0
37
Baudrate:
Setting the communication speed.
The change of this parameter requires
power-off/on cycle.
0 : 9,600
1 : 19,200
2 : 38,400
3 : 57,600
4 : 115,200
0
4
4
38
Restore ActPos/PT-No:
CK10 stores current position and
PT-No to non-volatile memory
when the power is turned off. This
parameter sets whether to restore them
or not.
* Note that the restored position value
may not be same with the real position.
0
:
Disable
1
:
Enable
0
1
1
39
Motor No Display:
CK10 can display the motor number
by blinking the LEDs. This parameter
sets whether to blink the motor
number. This function adds delay of a
few seconds to initialize.
0
:
Disable
1
:
Enable
0
1
0