16
Unit setting function
Function introduce
Select pressure unit according to customer requirements.
Note: Limited to the minimum display unit, there may be numerical deviations in unit exchange.
Please use linearity pressure setting to modify. Linearity pressure setting refer to page 10.
Caution:
The pressure unit is set according to the order specification before leaving the factory.
If you operate the function to change unit, the product will be inconsistent with the label content.
Press key for 2 seconds or more
Pressure unit
Unit
kgf/cm
2
bar
Psi
kPa
MPa
Min. display unit
0.01
0.01
0.1
0.001
1
Operation flow
Unlocking key
U n T
S A U
Save setting and
return to RUN mode
....
b A r
kgf/cm
2
bar
psi
MPa
kPa