17
●
Operation setting instructions
At Measurement Mode, press button for more than 3 sec.
to display [F-01]. Press or button to select other setting
functions.
Press for 3 sec. at Function Setting Mode to return to
Measurement Mode.
●
[
F-01
]
OUT1 Setting Selection
Press or button at Function Setting Mode to display
[
F-01
] [
oUt1
].
DIGITAL FLOW SENSOR
( INSTRUCTION MANUAL )
MF01
How to use
–
Operation setting instructions
F-01
oUt1
oUt2
rESt
F-02
00
F-99
Flashing
alternately
F-01
oUt1
Flashing
alternately
Flashing
alternately
Flow Sensor
Selected Mode
Fixed Hysteresis
Mode
Selected Output
NO mode
NC mode
Selected Mode
Set Value
Set Value
Selected Mode
Hysteresis
Mode
Window
Comparator
Mode
Accumulated
Output Mode
Accumulated
Pulse Output
Mode
Measurement Mode
Enter in each function setting
Press
button for
more than 3 sec.
Press
button
Press
button
Press
button
Press
button
Press
button to return to
Function Selection Mode
Press
button
Flashing
alternately
Flashing
alternately
Flashing
alternately
Flashing
alternately
Flashing
alternately
Function Selection Mode
Output Mode Setting
Set Value Setting
Fixed Hysteresis Setting
Output Type Setting
Select output mode
Press or button to
select output mode of OUT1.
4 output modes included.
OUT1 set value setting
Press or button to
adjust the set value.
Fixed hysteresis setting
Press or button to
adjust fixed hysteresis
value.
Hysteresis Mode [
HYS
]: [
FL-1
], [
FH-1
]
Window Comparator Mode [
y1n
]: [
FL-1
], [
FH-1
]
Accumlated Output Mode [
ADD
]: [
AdL1
], [
AdH1
]
OUT1 type setting
Press or button
to select OUT1 type.
* NOTE: The Accumulated Pulse Output Mode can only be set in
OUT1, and OUT2 does not have this setting.
* NOTE: Type setting will not display when Accumulated Pulse
Output Mode is set.
FLoy
FL-1
FH-1
oUt1
FLoy
FLoy
FLoy
FLoy
HYS
25.0
30.0
no
no
nC
HYS
oUt1
oUt1
Flashing
alternately
Flashing
alternately
Flashing
alternately
Flashing
alternately
Flashing
alternately
Flashing
alternately
Y1n
Add
PL5
* NOTE: Set value setting will not display when Accumulated Pulse
Output is set.
* NOTE: Fixed hysteresis setting will not display when Hysteresis
Mode, Accumulated Output Mode and Accumulated Pulse Output
Mode is set.