6.4.2
Check Weight values
-
Initialize Check Weighing (see chapter
)
-
Running Mode (see chapter
-
Printouts (see chapter
)
6.4.2.1
Initialize Check Weighing
The
Button pressed long generates a minus sign in input mode on Display-Count.
Pressing
(Exit) Button the initialization process is left at once without storing a
new input or limit.
Pressing
(No) or
button briefly the blinking limit value is cleared and a
blinking cursor is shown on the right side ready for a new input.
Initialization is possible on both scales.
1.
After a Check Mode is selected press the
Button briefly.
Weight
The previous low limit is also displayed on Display-PW with the unit which was
active before pressing the
Button.
On the Display-Count this weight value is also shown blinking. The Yellow LED is
on.
[SET.LOW] is displayed on the Display-Weight.
2.
Enter a numeric weight value via the key pad or a scanner which then is displayed on
Display-Count.
The input value isn’t blinking. Only the actual cursor position (marked by an
under line) is blinking. Input starts from the right side.
On Display-Count the same unit is shown as on Display-Weight.
3.
Accept the input by pressing
(Yes) Button briefly.
[SET.HI] is displayed on the Display-Weight.
Weight
The previous high limit is also displayed on Display-PW with the unit which was
active before pressing the
Button.
On the Display-Count this weight value is also shown blinking. The Red LED is on.
If
(Back) Button is pressed briefly then the input is rejected, the limit isn’t
changed.
Compact Scale Puro® Count
6 Application Programs
EN-24
Minebea Intec