Relay Box IE11357
5
Installation
§
Disconnect equipment from power
before opening the relay box.
§
To open the relay box, remove the
sechs screws from the cover plate.
§
Installing the cable gland and cable:
– Prepare the cable opening by breaking
out the pre-punched M20 disk.
– Guide the enclosed cable gland
(M20 x 1.5) into the opening and
secure it inside the housing with the
counternut (1).
– Route the cable (2) through the cable
gland. Tighten the screw-down nut
(3) until the sealing clamp (4) forms a
slight ridge.
§
Mount the cable on the relay card in
accordance with the relevant wiring
diagram.
1
2
3
4
Summary of Contents for IE11357