Switch setting
PR 5900-1
Switch setting
PR 5900-2
Switch setting
PR 5900-3
Coniguration
ON: -
OFF: S1, S2, S3, S4,
S5, S6
ON: -
OFF: S1, S2, S3, S4,
S5, S6
ON: S1, S2, S3
OFF: S4, S5, S6
[Operating] - [System setup] - [Connected
devices] - [PC via EW-Com] - [Interface] -
[Built-in RS
‑
485]
4.5.7.4
Connecting an IS platform via RS-485 (2-wire)
One IS platform scale with xBPI or SBI protocol can be connected via the RS-485 interface
(2-wire).
RS-485
PR 5900
PR 5900
RxD/TxD-P
RxD/TxD-N
TxB
TxA
RxB
RxA
GNDI
S4
S1
S2
S3
1K6
1K6
120
120
DC
DC
S5
1K6
S6
1K6
1
2
3
4
5
6
↓
O
N
K
A
B
J
L
C
H
M
D
G
F
E
L
A
E
RxD - TxD - P
RxD - TxD - N
GND
RS-485
2
1
3
4
①
IS platform xBPI protocol (slave)
②
Half duplex
③
12-pin male connector
④
AC/DC adapter
Switch settings PR 5900
Coniguration PR 5900
ON: S2, S3, S4, S5, S6
OFF: S1
[Operating] - [System setup] - [Weighing points] -
[Weighing point X] - [xBPI scale] - [Interface] - [Built-
in RS
‑
485]
4 Device installation
Process Controller Maxxis 5 PR 5900