+ Meas.
– Meas.
+ Supply
+ Sense
– Sense
– Supply
Ground
analog
bu
rd
wh
bk
gy
gn
GNDA
PR 5900
PR 5900
1
2
4
3
①
Screen
②
Screen clamping rail or cable gland
③
Equipotential bonding conductor
④
or
4.6.4.4
Connecting up to 8 load cells (650
Ω
) using a 6-wire connection cable
Connections are made via cable junction box PR 6130/.. using connection cable PR 6135/..
or PR 6136/... .
Note:
The colors listed here apply for the Minebea Intec load cell and connection cables of
type "PR …"
Color code
bk
=
Black
bu
=
Blue
gn
=
Green
gy
=
Gray
rd
=
Red
wh
=
White
For additional information on the connection of load cells and cable junction boxes,
refer to the corresponding installation manuals.
4 Device installation
Process Controller Maxxis 5 PR 5900
Minebea Intec
EN-77