9. Fieldbus interface | 9.2 - Scale protocol | 123
9.2.5.12 Function number 80–89: state-controlled action bits (write)
Note:
Only setting and resetting of single bits is possible.
When changing a bit from 0 to 1, the corresponding action starts. After han
dling the command, the bit must be reset. Application: The master writes
cyclically.
The bit is set as
Write_Value_Select
with the specified number (see Chapter
).
The bit is reset at the specified 128.
Function number 80
SetZero
Set the gross weight to zero.
Function number 81
SetTare
The weighing point is tared.
Function number 82
ResetTare
Reset tare.
Function number 83
SetTest
Start the ADC test.
Function number 84
ResetTest
Finish the ADC test.
Function number 85
ResetPwf
Reset the
PowerFail
bit (function
number 1; the bit was set after
"power on").
Function number 86
SetFixTare
Taring with weight in numerical
address D31 "FixTare".
Function number 87
GetFixTare
The current gross weight is copied
to the numerical address D31.
Function number 89
ResetError
The
CmdError
error bit is reset.