Filling starts again with the rising edge and the system leaves the hold status (hold state)
and goes back to the ready status (ready/idle).
12.3.4.3
Filling report
The filling results are stored after filling and only overwritten when there is a new result.
12.3.4.4
Filling error
Last_Error
The last error number is retained until it is reset.
The possible error numbers are listed in Chapter
.
12.3.4.5
Reading the material table
The material parameters can be read from the material table of the device (PR 5230).
Procedure:
12.3.5
Setup of the fieldbus interface
For description of the data types see Chapter
.
12.3.5.1
PLC → write window EasyFill
Bytes 0
63
Name
Type of data
Function
Byte 0
TableSelect
USINT
The first byte controls (multiplexes) the da-
ta written in the read window by the device.
A "0" describes the read window according
to the system data layout.
A "1" copies the material data to the read
window.
1.
Write the material ID to byte 3.
2.
Write command 1 to byte 0 in order to see the material parameters on the read side.
3.
Write command 0000 0001 to byte 2 in order to copy the material parameters from
the material table.
If all parameters of the material were available to be read, 1000 0000 is set to
byte 2.
4. Write command 0 to byte 0 in order to see the filling parameters again on the read
side.
12 Fieldbus interface
Transmitter in field housing PR 5230
EN-271
Minebea Intec