Pin allocation acc. to
DIN 41642
Signal
Color acc. to
DIN 47100
Description
1 ----------------------
DO1
yellow
not inverted, data output
2 ----------------------
DI1
gray
not inverted, data input
3 ----------------------
GND
brown
signal ground
4
not connected
5
not connected
6 ----------------------
IDO1
green
inverted, data output
7 ----------------------
IDI1
pink
inverted, data input
8
not connected
9
not connected
* only if necessary
4.6.12.1
LEDs in the module cover
The module cover can be found at the rear of the device.
⑥
⑥
LED 1
CC/RC
LED 2
BA
LED 3
RD
LED 4
TR
Off
Constant green
Cable OK, no reset
mode in the master
Bus is active
PCP communication
is active, hold = 500
ms
Constant red
Remote bus is not
active
4.6.12.2
Selecting the status LED and transfer rate
LED
⑦
lights up when the operating voltage is applied.
The transfer rate is selected using the 2-pole jumper
④
.
-
3 — 1 = 2 Mbit/s
-
4 — 2 = 500 kbit/s
4 Device installation
X3 Process Indicator PR 5410
EN-101