Note:
Error messages, calibration see Chapter
.
7.14.8.1
Calculating SPAN value
SPAN indicates the equivalent input voltage in mV/V related to the maximum load (Max)
of the scale.
It is calculated as follows:
* load cell sensitivity C
n
= rated output C
n
(see technical data of the load cell)
The input voltage in mV/V equivalent to the dead load can be calculated by using the
dead load rather than the maximum load using the formula specified earlier.
1.
Calculating SPAN value for Max and, if necessary, for the dead see Chapter
2.
Press the [by mV/V] softkey.
3.
Entering the SPAN value for Max and, if necessary, for the subsequent correction of
dead load (see Chapter
).
4. Confirm the entries.
Weight value, weight unit and measuring signal in mV/V corresponding to this
value are displayed in the line [Calibrated at].
The verification is displayed by "Setting Span mV/V
".
7 Commissioning
X3 Process Indicator PR 5410
EN-167
Minebea Intec