NOTICE
Potential network problems
A unique device name must be assigned for the hardware configuration and
assignment/download.
Note:
See Chapter "Description of the I/O Area"
Example:
The gross weight should be read.
I/O size = 8 bytes, counted from byte 0–7
7.17.5.4
EtherNet-IP settings for Rockwell workstation
Requirements:
-
PR 1721/37 DeviceNet EtherNet-IP is installed.
Procedure:
Note:
Further details can be found in the supplementary application manual "How to
"
(available upon request from technical.support.hh@minebea-intec.com).
Note:
See Chapter "Description of the I/O Area"
Example:
The gross weight should be read.
I/O size = 8 bytes, counted from byte 0–7
7.17.6
Network parameters
Under this menu item, you can define the network parameters for the network
connections (built-in LAN adapter).
2.
Enter the IP address and network mask under
- [Fieldbus parameter] and
confirm.
3.
Add the PR 5410 device to the project and assign the I/O ranges.
4. Assign the instrument name to the PR 5410.
1.
Enter the IP address and network mask under
- [Fieldbus parameter] and
confirm.
2.
Register the file "sag_5410_Ethernetip.eds" using the "Hardware Installation Tool".
3.
Select and insert the instrument from the catalog into the I/O configuration.