4.6.11
ProfiBus-DP interface
The ProfiBus-DP interface card has the type designation PR 1721/31.
Communication protocols and syntax comply with the ProfiBus-DP standard to IEC 61158,
with transfer rates up to 12 Mbit/s.
Connection to the ProfiBus is established using the 9-pin D-Sub female connector
②
on
the back of the device.
The card is inserted into "Slot 4"
①
(see Chapter
Technical data
Description
Data
Transfer rate
9.6 kbit/s to 12 Mbit/s, auto baud rate detection
Connection mode
ProfiBus network,
connections can be made/released without affecting other
stations.
Protocol
PROFIBUS-DP-V0 SLAVE to IEC 61158
-
Mono or multi-master systems are supported.
-
Master and slave devices, max. 126 nodes possible.
-
Watchdog Timer
⑤
(see Chapter
)
Configuration
GSD file "SART5410.gsd"
Potential isolation
Yes, optocoupler in lines A and B (RS-485)
X3 Process Indicator PR 5410
4 Device installation
Minebea Intec
EN-94