36
Procedures
Press the “ENTER” key.
The load display will show “
−−−−−
” with
lighting on and off, and Span adjustment will be
started.
11
Warning
:
At the same time, be careful
not to apply load vibration due to vibration
and so on.
When load vibration is applied, it may have
the possibilities that span will become
unstable, and precise reading of span will
not be obtained.
After completing above, the load display will
become “T
−
END”.
However, when the load corresponding to the
maximum display value is out of the range from
0.2 mV/V to 3.1 mV/V, the error code in the right
figure will display for about 2 s, and afterwards
Error code
figure will display for about 2 s, and afterwards
load display will be “SPAN”, then will returns to
step 9.
SPN
−
L
:
Span point
−
over
SPN
−
H
:
Span point
+
over
Error code
Press the “ENTER” key.
Quitting from the “ACAL” mode, the present load
value will show on the load display.