13
⑤
Error assistance code (4 stations, 2 stations, 1 station)
Area for displaying the error No. generating in the main body of the indicator
Data type
: 16 bits binary
Setting range
: 0
~
255
Error code
Error
assistance
code
Contents
0 0
No
error
1
(Weighing
sequence error)
1
SQERR 0 :
When measurement is stopped compulsorily by inputting the
temporary
stop while weighing.
2
SQEER 1 :
When the condition of SAFETY CHECK is not satisfied.
3
SQEER 2 :
When the load value is under even if the supplementary flow is
executed.
4
SQEER 3 :
When there is contradiction in the amount of the comparison
value.
5
SQEER 4
:
When the batching time exceeds the limited time.
6
SQERR 5 :
When the discharging time exceeds the limited time.
7
SQERR 6 :
When the gross value < Final in discharge control.
8
SQERR 7 :
When the net value > (Final – free fall) in the start
9
SQERR 8 :
In controlling the nozzle, when the change of the load value
exceeds the zero band.
10
SQERR 9 :
The measurement begins in the condition that [START ABOVE
ZERO BAND] is [VALID], however the container is not put on the
measuring section.
2
(Operation error)
1
Zero set error
In case of execute ZERO out of range of zero
2
A/Z error
In case of execute TARE out of range of tare.
3
(Other error)
3
A/D conversion error.
31
EEPROM writing error.
32
EEPROM reading error.
4
(
Calibration
error)
0 TE-L
error
1 TE-H
error
2 SP-L
error
3 SP-H
error
4
When the setting is Span adjustment value > Weighing capacity.
99
(Setting error)
0
Receiving undefined command
When undefined data is set at command No.
1
Setting range error
2 Read-only
state
•
Refer to Error display in main body instruction manual about the contents of Error code.