Relay Box Mounting Instructions 

For details of how to mount the overall system, see the Integrated Mold Sensing System MIS-202 Instruction Manual 
(EN294-1906*). 
 

Relay Box Mounting 

  The relay box can be mounted either by attaching using the magnets or by bolting using the mounting bolt holes. 

  When mounting using the magnets, attach to the moving part (platen) of the mold clamping unit. Also make sure the 

operating temperature does not exceed 70 °C here. 

  If the magnets do not provide sufficient magnetic attraction or when attaching to a location where the operating 

temperature exceeds 70 °C, the relay box should be bolted to the mold. 

 
 

   

 

 

 

 
 
 
 

Handling Precautions 

 

The relay box ambient temperature should be in the range 0 °C to 70 °C when mounted using the 
magnets, and in the range 0 °C to 100 °C when mounted using the bolts. 

 

When mounting using the magnets, check that there is sufficient magnetic attraction. If the 
magnetic attraction is insufficient due to the mounting surface conditions, or if the relay box is to be 
used for extended periods, mount using the bolts. 

 

Keep credit cards and cash cards away from the magnets, as the magnetism may render them 
unusable.   
Likewise, the magnets may also cause malfunctions if precision equipment such as PCs and mobile 
phones are close by. 

 

Be sure to remove the magnets before mounting the relay box using the bolts. Otherwise, the box 
will not make close contact with the mounting surface and will not be securely attached. 

 

Be sure to use bolt mounting when mounting the relay box on a mold. 

 

Mount using two M4 hex socket head bolts each on 
either side. (M4 tapped holes must be drilled in the 
mounting surface.) 

Be sure to remove the magnets when using 
bolts to attach the relay box. The magnets can 
be removed by removing the screw in the center 
of each magnet.

Removing the magnets 

Bolt mounting 

M4 hex socket head bolts ×4 

Magnets ×2

Magnet mounting screws ×2

Summary of Contents for MIS-304-P

Page 1: ... 0 C to 100 C when mounted using the bolts When mounting using the magnets check that there is sufficient magnetic attraction If the magnetic attraction is insufficient due to the mounting surface conditions or if the relay box is to be used for extended periods mount using the bolts Keep credit cards and cash cards away from the magnets as the magnetism may render them unusable Likewise the magne...

Page 2: ...llowing minimum bending radii for the cables must be adhered to when installing to prevent cable disconnection Pressure sensor cables Clamped sections 50 mm or greater Movable sections 50 mm or greater Temperature sensor cables Clamped sections 70 mm or greater Movable sections 100 mm or greater When connecting a relay cable to a relay box tighten the screws on both sides of the D sub connector Fl...

Page 3: ...sumi_Inc Sensing Device Business Unit Exterior Diagram Units mm 102 6 15 10 111 6 4 5 7 5 25 40 35 4 4 φ4 5 40 4 マグネット 4 5 102 6 111 6 15 10 7 5 25 40 35 4 4 φ4 5 40 4 マグネット 53 2m FA409 548 2M 53 2m FA409 549 2M Magnet Magnet ...

Page 4: ...ing magnets Casing material SUS430 Applicable transducers LSMS S06 series 20K 50K 100K 200K 500K 1T 3T Applicable amplifiers MIS 202 PT MIS 202 PP General Specifications MIS 304 T Operating temperature range 0 C to 70 C 0 C to 100 C when not using magnets Operating humidity range Max 85 RH with no condensation Storage temperature range 10 C to 70 C 10 C to 100 C when not using magnets Vibration re...

Reviews: