User Manual of DH-300/400 Full Automatic Soldering Robot
45
3.1.7 Menu Structure Table
Startup->
Reset->
|--Task selection
|---X→
|
|---X←
|
|---Y↑
|
|---Y↓
|
|--- OK <-
|
|--- Task selection <-
|-- Function
|-X→-|---1 Zero correction--------------------|---OK<-
|---2 Load mode (acceleration)--------|---OK<-
|---3 Adjustment unit setting of reference point
--------------------------------------------|---OK<-
|---4 Adjustment height setting of reference
point--------------------------------------|---OK<-
|---5
XY-axis
idling
speed
--------------------------------------------|---OK<-
|---6 Z-axis idling speed ---------------|---OK<-
|---7 Task restoration -------------------|---OK<-
|---8 Setting of automatic delay operation
--------------------------------------------|---OK<-
|---9 Y-axis positioning correction distance
--------------------------------------------|---OK<-
|---11 Deletion of current task --------|---OK<-
|---12
Setting
of
automatic
deceleration
--------------------------------------------|---OK<-
|---13 Counting function of welding spots
corresponding to task------------------|---OK<-
|-Function 1 parameter X→, X←, Y↑, Y↓, Z↑, Z↓-|--- 0-2 ----|-OK<-
|-Function 2 parameter X→, X←, Y↑, Y↓, Z↑, Z↓-|-- 5-500 --|-OK<-
|-Function 3 parameter X→, X←, Y↑, Y↓, Z↑, Z↓-|-- 1-50 ----|-OK<-
|-Function 4 parameter X→, X←, Y↑, Y↓, Z↑, Z↓-|--- 0-10 ---|-OK<-
|-Function 5 parameter X→, X←, Y↑, Y↓, Z↑, Z↓-|-- 1-800 ---|-OK<-
|-Function 6 parameter X→, X←, Y↑, Y↓, Z↑, Z↓-|-- 1-400 ---|-OK<-
|-Function 7 parameter X→, X←, Y↑, Y↓, Z↑, Z↓-|---- 0-1 ----|-OK<-
|-Function 8 parameter X→, X←, Y↑, Y↓, Z↑, Z↓-|-- 0-500.0 -|-OK<-
|-Function 9 parameter X→, X←, Y↑, Y↓, Z↑, Z↓-|---- 0-x ----|-OK<-
|-Function 11 parameter X→, X←, Y↑, Y↓, Z↑, Z↓-|--- 0-1 ----|-OK<-
|-Function 12 parameter X→, X←, Y↑, Y↓, Z↑, Z↓-|-- 5-600 ---|-OK<-
|-Function 13 parameter X→, X←, Y↑, Y↓, Z↑, Z↓-|----- 0 ----|-OK<-