User Manual of DH-300/400 Full Automatic Soldering Robot
63
10
E.300
System not reset
1. The system is not reset.
1. Perform the reset
operation.
11
E.302
Welding system
abnormal
1.
The
photoelectric
detection of the cylinder is
wrong, and it is necessary to
perform
the
movement
operation.
1. Check whether the air
source is connected or
the
photoelectric
detection position of the
cylinder is correct.
12
E.402
Welding system
not ready
1. When the task starts to
run, manual tin feeding,
return
and
blowing
operations or vertical action
of the cylinder are being
performed.
1. When pressing “Run”
or “Pedal” to run the
task, do not perform
manual
tin
feeding,
return
and
blowing
operations or vertical
action of the cylinder.
13
E.502
Communication
between
welding system
and
motion
system failed
1. The communication chip
is
damaged
or
the
communication wiring is
wrong.
1. Press “OK” key again
to select the task to
check whether it is
correct. If not correct,
please
contact
the
after-sales
service
department.