User Manual of DH-300/400 Full Automatic Soldering Robot
67
4. After the machine operates for a period of time, if X-axis, Y-axis and
Z-axis parallel moving mechanism has the step losing phenomenon during
operation, the pre-tightening force of the synchronous belt may be
decreased. It is necessary to inform our after-sales service staff to maintain
the machine on site.
5. It is necessary to open the bottom box cover to remove the dust for the
internal circuit boards and other components of the machine every three
months to prevent the electric control components from being damaged.
Methods: Remove screws used for fixing the bottom box cover, open the
cover, and blow the dust on the circuit boards away with clean compressed
air.
Y-axis Double-layer
Carrying Plate
Y-axis Middle
Baffle Plate
Y-axis Linear
Guide