User Manual of DH-300/400 Full Automatic Soldering Robot
47
3.2 Description of Soldering Process Panel
There are 4 inching buttons on the spot welding process control panel (as
shown in the above figure), and these buttons are marked with “Tin Feeding”,
“Tin Return”, “Tin Blowing” and “Cylinder↓” respectively.
1.
“Tin Feeding” button: Long press “Tin Feeding” button to carry out
manual tin feeding.
2.
“Tin Return” button: Long press “Tin Return” button to carry out manual
tin return.
3.
“Tin Blowing” button: After the machine is reset, long press “Tin
Blowing” button to carry out manual tin blowing, and release the button to
stop tin blowing.
4.
“Cylinder↓” button: In the cylinder mode, inch “Cylinder↓” button to lift
or drop the welding head cylinder.
3.3 Temperature Control System
3.3.1 General Temperature Setting
Note: Confirm that the soldering station is in the temperature adjustable
state (enter the correct password or the password is the original password
000). When setting the temperature, the heating element is powered off. If
pressing “SET” key for less than 1s, the current set temperature will be
displayed for 2s, and then the soldering bit temperature will be displayed.
Example: Change 400ºC to 350ºC
Press and hold “SET” key for 1s at least, and then the leftmost digit place
(hundreds place) will flash (as shown in the figure below), indicating that the
temperature control system is in the temperature setting mode, and the
hundreds place can be set; press “▲” or “▼” to adjust. Press “SET” key again,
and then the middle digit place (tens place) starts flashing, indicating that the