INSTALLATION GUIDE - SK CONVECTORS
1. UNIT DESCRIPTION
A skirting-type heating unit which uses the convecti-
on principle. Since the heater fully uses physical laws
of thermodynamics it represents one of the most effi-
cient methods of interior heating.
Benefits of skirting convectors with fan:
High output
› Possibility of using forced convection for heating
(with fan)
› Silent operation
› Low hot water consumption
› Very short response time
› Design
› A great advantage of these convectors is the
possibility of installation in a skirting (under kitchen
cabinets, stairs, wardrobes, etc.). This advantage
is particularly practical in applications where we
do not want to disturb the aesthetic experience
of the interior with wall-mounted or free-standing
convectors or other heating units, and where suffi-
cient heating output is required at the same time.
fig. 1:
COMPONENTS OF THE SKIRTING CONVECTOR:
2. CONTENTS OF THE BOX
3. TECHNICAL PARAMETERS
1. TROUgH – an all-aluminum structure which holds
all components (AiMg3).
2. HEAT EXCHANgER – copper pipes with pressed-
-on aluminum fins through which the heating water
flows.
3. fAN – used for forced convection.
4. METAL COVER – used as a lid of the trough (po-
sition 1) and protects all components located in it
from damage.
5. DiRECTiONAL METAL PLATE – improves the con-
vector output thanks to ideal air flow around the
heat exchanger.
6. fRONT gRiLLE – the only visible part after instal-
lation.
7. gRiLLE SiDE PLATE – limits the space (horizontally)
for placement of the grille.
8. EB CONTROL UNiT – fan motor control unit.
9. TEMPERATURE SENSOR – heat exchanger tempe-
rature sensor
10. CABLE gROMMET – intended for 12VAC power
supply cable.
11. gUiDE BAR – used for exact positioning of the con-
vector.
12. RUBBER ANTi-ViBRATiON RiNg – used for atte-
nuation of vibrations and for mounting of the metal
covers and fan modules.
13. SCREW – for fixing the guide bars (position 11) to
the floor, step.
Contents of the box
Position
SK
Convector
Trough
1
1
Heat exchanger
2
1
fan
3
1
Metal cover
4
1
Directional metal plate
5
1
front grille
6
1
grille side plate
7
2
EB control unit
8
1
Temperature sensor of the
exchanger
9
1
Cable grommet
10
1
guide bar
11
2
Accessories
Anti-vibration pad
12
4
Wood screw 3 x 30
13
4
Screw anchor 3
14
4
Hose g ½´´ - 41 mm
15
2
Ball valve – straight
16
1
Control screw fitting – straight
17
1
gasket KLiNgERSiL C4400
18
4
Each position in the table corresponds to figure No.
1 – see next page.
14. SCREW ANCHOR – for fixing the screw in concre-
te floor.
15. HOSE – the bellows hose is a stainless hose in-
tended for fitting connection to the convector ex-
changer.
16. STRAigHT BALL VALVE – a valve used to shut off
the heating water supply to the convector.
17. CONTROL SCREW fiTTiNg - a valve that controls/
adjusts heating water flow.
18. gASKET – seals joints between valves, hoses,
and exchangers (KLiNgERSiL C4400). MiNiB, a.s.
recommends this sealing as the optimal sealing
solution because other materials (rubber, NBR,
silicon) do not provide the required sealing cha-
racteristics.
Use: dry environment, according to the specification.
› Maximum operating pressure: 1 MPa.
› Maximum operating temperature: 90 °C.
› Operating medium: water. The use of other media
is prohibited. Water may not be mixed with other
substances, such as antifreeze fluids!
› Environment: interiors with temperatures ranging
b5 °C and +40 °C.
› Power supply: 12 V AC from a suitable transfor-
mer for the given environment and convector fan
types.