Chapter 5. Machine adjustment and setting up
EN
5.1.2. Luminous column
The machine is equipped with a luminous column with multicolour LED lights (green, yellow, red) which, based on the
combination of colours and buzzer, signals the machine status at all times.
Machine status
Luminous column
Buzzer
Start in Manual
Start in Automatic
Green
No
Green
Green
Warm-up
Maintenance
Automatic stop
Manual stop
Homing
Yellow
No
Yellow
Yellow
No power
Red
Yes
Red
Red
Safety excluded during Start
Red
Yes
Green
Green
Safety excluded during Stop
Red
Yes
Yellow
Yellow
Roll end in Automatic Start
Red
Yes
Green
Green
5.2. Start-up
Turn the main switch (Q1) into pos. 1 and press the “RESET” (S2) button.
The display switches on and the screen with the “minipack-torre” logo appears. Press the logo.
The main screen is displayed:
When the machine is switched on, the numbers that indicate the temperature of the
front and side sealing bars start flashing. Once the bars have reached the
programmed temperature, they stop flashing. Until the bars reach this temperature,
the cycle may only be started in MANUAL mode (not AUTOMATIC mode).
During the heating phase the "Alarm" button is red since the "A024: MACHINE
HEATING" alarm is active. Once the set temperature has been reached, the alarm
resets itself and the button becomes green..
37
Summary of Contents for MF21BA54