Chapter 5. Machine adjustment and setting up
EN
SEALING HEIGHT
[mm]
56MPE 56MPS
Adjusts the sealing position with respect to the belt. Values: AUTO / MAN.
If set at AUTO sealing is performed at half the height of the product. Ideal for standard
products.
If set at MAN sealing is performed at the set measurement (measured starting from
outfeed belt surface). Values: 0 ÷ 120.
OPENING SEALING BAR
[mm]
56MPE 56MPS
Adjusts the sealing bar aperture. Values: AUTO / MAN.
If set to AUTO, opening the sealing bars is defined by the program.
If set to MAN, opening is defined by the user (e.g.: to increase the speed of packaging,
set the minimum opening of the sealing bars in order to reduce the closing and
opening time).Values: 20 ÷ 100.
TYPE OF PHOTOCELL
56 56CS 56MPE 56MPS
This function enables the operator to select the pack reader photocell.
Values: HORIZ / VERT.
PHOTOCELL FILTER
[s]
56 56CS 56MPE 56MPS
Adjusts the length of time for which the photocell must ignore a missing signal
(advisable when processing irregular product formats).
Values: 0 ÷ 1.
The next 2 screens allow data to be entered relating to the manual settings to be
applied to the machine, so that every time this program is loaded, that memorised
settings can be applied.
POSITION FILM TENSIONING ROLLERS ON TRIANGLES
56 56CS 56MPE 56MPS
Enter the position of the wheels (R6) (OPTIONAL) with reference to the millimetre
scale (X3) (see paragraph 5.4 PHASE 6).
The function can be ON only if it is enabled in OPTIONALS.
BLOW AIR ACTIVATION
56 56CS 56MPE 56MPS
Indicate whether the "AIR BLOW" kit is applied (ON) or not (OFF) for this program.
Values: ON / OFF.
The function can be ON only if it is enabled in OPTIONALS..
BELT SPEEDS
[%]
56 56CS 56MPE 56MPS
Adjust the infeed belt (IN) and outfeed belt (OUT) speeds from 6m/min. to 30m/min.
Belt speed is identical for both.. Values: 20 ÷ 100.
BELT REVERSAL
[mm]
56 56CS 56MPE 56MPS
It can be set only if the “PACKET LENGTH” function is MAN. Adjusts the distance
between the products. After the belts have stopped running, the infeed belt (IN) runs
backwards in order to move the product back by the programmed distance.
Values: 0 ÷ 500.
BELT STOP AT SEALING
56 56CS 56MPE 56MPS
This function enables the operator prevent infeed belt (IN) from running during the
sealing phase in order to ensure that the package is processed correctly.
Values: ON / OFF.
LOAD BELT PHOTOCELL
56 56CS 56MPE 56MPS
When this variable is set to ON, the machine prevents the infeed belt (IN) from running
when in automatic START cycle, and activates it only when the load belt photocell is
activated. (OPTIONAL).
The function can be ON only if it is enabled in OPTIONALS.