Note: The auto learning function will only
mandate within 60 seconds when turning the
fan’s AC power ON.
1. Select desired frequency from the back of
transmitter.
2. Press the transmitter’s “SET” button, and hold
the “SET” button for over 5 seconds. Once the
receiver has detected the frequency, the fan will
automatically begin to operate and start to
rotate in the counter-clockwise direction and on
the highest RPM for 3 minutes. When
counter-clockwise rotation has finished, the fan
will automatically reverse to clockwise direction
again to the highest RPM for 3 minutes. Fan will
shut off when the self calibration test has
finished. The total self calibration test will last
about 6 minutes.
Note: During self calibration test, the remote
will be non-function.
Note: The learning frequency function and self
calibration test will continue to retain the last
set frequency and calibration set even when the
AC power is shut off. If the frequency is
changed the self calibration test will occur
again.
1. Lock position: The DC motor has a built-in
safety against obstruction during operation. The
motor will get locked operation and disconnect
power after 30 seconds if interruption occurs.
Please remove obstacles before re-set.
2. Over 38W protection: When the receiver
detects motor power consumption which is
greater than 38W, the receiver’s power will stop
and operation will be immediately discontinued.
Turn the receiver power on after 5 seconds.
3. “D” and “ON” dip switch:
The “D” selection is the light dimmable selection
and is to be used with all bulbs except for CFL
bulbs. The “ON” selection is For CFL bulbs.