(2720)A 45
REP
AIR GUIDE
■
■
■
■
■
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
■
■
■
■
■
Fig. 2
Fig. 2
Fig. 2
Fig. 2
Fig. 2
■
■
■
■
■
Fig. 3
Fig. 3
Fig. 3
Fig. 3
Fig. 3
Adjustment of white balance (WB)
Required equipment
Color Viewer LV-1450DC
Light balancing filter LB200
White chart
PC with preinstalled the 2720 adjustment program
USB-500 (USB cable)
AC-1L/AC-11
Preparation of the adjustment
Perform the adjustment 30 minutes or longer after turning on the Color Viewer.
The Color Viewer should be checked and adjusted according to its maintenance instruction on page 23 in
2783 repair guide.
1. Start up the 2720 adjustment program.
2. Connect the camera and PC with USB-500, and click "START" after confirming the USB connection.
3. Set the camera and the measuring instrument as shown on the Fig.1.
4. Set the lens block of the camera to "Wide position."
Procedure of the adjustment
1. Click "WB" of the adjustment menu.
The adjustment is automatically started.
2. Follow the message, "Please set a camera toward C-LIGHT!" Set "Light source C," and click "OK."
(Fig. 2)
The adjustment is automatically started.
Setting the Light Source-C
Affix the Scotch tape (Sellotape) fitting the Light Balancing Filter LB200 securely to the zoom lens
shown in Fig. 3, then set the Color Viewer apart from the front of camera.
3. The adjustment is completed when "OK" is displayed on the adjustment menu.
Camera:
Camera:
Camera:
Camera:
Camera:
Lens block: Wide-angle position
Lens block: Wide-angle position
Lens block: Wide-angle position
Lens block: Wide-angle position
Lens block: Wide-angle position
Color Viewer
Color Viewer
Color Viewer
Color Viewer
Color Viewer
LV-1450DC
LV-1450DC
LV-1450DC
LV-1450DC
LV-1450DC