(2181) 51
REP
AIR GUIDE
Memorize the number printed on the bar code put on the CCD ASSY, when CCD ASSY (2181-0271) or
MAIN BOARD ASSY (2181-0455) is replaced.
If CCD ASSY (2181-1001) is exchanged for new one, exchange the bar code on the BACK SUS PLATE
(2181-1001) for the bar code put on the new CCD ASSY.
Required equipment
PC with preinstalled the 2181 adjustment program
CF card for Adjustment
AC Adapter AC-11
USB-2 (USB cable)
* Use the AC adapter (AC-11) not batteries when adjusting.
Preparation of adjustment
Set camera to adjustment mode. Refer to Starting up the 2720 adjustment program . (P49)
Adjustment process
1. Click VSUB in adjustment menu.
CCD V-sub Adjustment windows is appeared.
2. Input memorized number on the CCD ASSY and click OK .
3. OK is displayed and adjustment is complete.
Adjustment of CCD Vsub voltage
Summary of Contents for DYNAX 7
Page 6: ...6 2181 REPAIR GUIDE...