3
Getting to Know Your Copier
3-2
Rev. /
EP3010
CAUTION
Danger of burns from the Heating Unit!
The Heating Unit may reach temperatures of up to 120°C.
Ü
To tilt the Heating Unit, touch the lever with the yellow marking only.
2
1
3
4
6
5
Pos.
Specification
Description
1
Lock Release Lever for the
Copier Cabinet
Raise this lever to open the top section of the Copier
Cabinet
2
Toner Bottle Holder
Take this holder out to replace the Toner Bottle
3
Original Cover
Holds the original in place on the Original Glass
4
Original Glass
Place the original on the Original Glass with the side to
be copied face down
5
Corona Cleaning Unit
(top/bottom)
Pull the Corona Cleaning Unit out using the levers to
clean the corona wires
6
Heater Unit Lever
Tilt this lever to the right to move the Heater Unit if
required to clear a paper misfeed