Interleaf EP5000/EP4000 DIS/REASSEMBLY, ADJUSTMENT
97.04.01
D-59
(7) Cleaning of Fusing Thermoswitch TS1
1156D094AA
(8) Replacement and Cleaning of the Cleaning Roller
1156D089AA
1136D232AA
(9) Replacement and Cleaning of the Upper Fusing Roller
1156D090AA
1136D233AA
1.
Remove the Temperature Detector Assy.
2.
Using a soft cloth dampened with alcohol, wipe clean the
thermoswitch.
1.
Remove two screws and the Upper Cover.
2.
Remove the Cleaning Roller.
3.
Replace the Cleaning Roller with a new one.
4.
Using a brush, whisk dust off the Cleaning Roller.
1.
Remove the Upper Fusing Roller.
2.
Replace the Upper Fusing Roller with a new one.
3.
Using a soft cloth dampened with alcohol or silicone oil,
wipe clean the Upper Fusing Roller.