Interleaf EP5000/EP4000 DIS/REASSEMBLY, ADJUSTMENT
97.04.01
D-62
1156SBD0300A
ADJUSTMENT
3
1156SBD0301A
3-1. JIGS AND TOOLS USED
z
Important
D
When adjusting the positions of the Scanner and Mirrors Carriage, use jigs number
Â
and
Ã
.
D
When adjusting the gap between the Doctor Blade and Sleeve Roller, use jigs number
Ä
and
Å
.
D
When adjusting the position of the PC Drum Paper Separator Fingers, use jigs number
Ä
and
Æ
.
À
Front Door Interlock Switch
Actuating Jig
Á
Predrive Inhibit Switch
Actuating Jig
Â
Scanner Positioning Jig
Ã
Scanner/Mirrors
Carriage Positioning Jig
Ä
Sleeve/Magnet Roller
Positioning Jig
Å
D.B. Adjusting Jigs
Æ
PC Drum Paper
Separator Finger
Positioning Jig
1136D006AA
1136D003AA
1136D002AA
1136D005AA
1136D001AA
1136D004AA