Interleaf EP5000/EP4000 DIS/REASSEMBLY, ADJUSTMENT
97.04.01
D-80
(9) Adjustment of Reference Position of the 1st/2nd Drawer
z
Requirement
1134D196AB
Dimension A
z
Important
This adjustment should be made after the “adjustment of zoom ratio in the crosswise direction”.
1136D030AA
1134D146AA
D
If dimension A on the copy is longer than 22 mm, move the Positioning Plate to the front of
the copier.
D
If dimension A on the copy is shorter than 18 mm, move the Positioning Plate to the rear of
the copier.
Adjusting Instructions
1139U037AA
D
Dimension A on the copy of the GTC-test chart should mea-
sure 20 mm
"
2.0 mm in the full size (
1.000) mode.
1.
Place the GTC-test chart face down on the Original Glass
and align its rear left corner with the reference marker on
the Original Width Scale. Then, lower the Original Cover.
2.
Feeding three sheets of A3 or 11”
17” paper from the 1st
Drawer, make two full-size copies.
3.
Check if dimension A (from the edge up to the reference
line) on the third copy is up to the specifications.
4.
If dimension A deviates from the specifications, slide out
the 1st Drawer. Then, loosen the three screws shown on
the left and move the Drawer Positioning Plate to the front
or rear as necessary. (Use the same procedure for the 2nd
Drawer.)
5.
After the adjustment, loosen the four screws shown on the
left and adjust the position (tilt) of the Drawer Cover.