Interleaf EP5000/EP4000 TROUBLESHOOTING
97.04.01
T-26
Symptom
Step
Check Item
Result
Action
Paper is stationary
at the Vertical Trans-
port Section
7
Does CL1 operate proper-
ly?
Using the IC Port Data
Check function, set the data
of PWB-A (IC4A) BPA3 to
“0.”
YES
Check the drive transmis-
sion path.
Run the “Controller Board
YES
Change PWB-A.
8
Check.” Is the malfunction
code “C0321” displayed?
NO
Change CL1.