Interleaf EP5000/EP4000 TROUBLESHOOTING
97.04.01
T-35
Symptom
Step
Check Item
Result
Action
D
Paper is not tak-
en up at all.
1
Does the paper being used
meet product specifications?
NO
Instruct the user to use
the paper that meets
product specifications.
D
Paper is station-
ary before the
Paper Take-Up
2
Is the paper curled, waved, or
damp?
YES
Change the paper.
Instruct the user in how
to store the paper.
Sensor.
4
Are the Paper Take-Up Roll and
Separator Roll deformed, worn,
or dirty with paper dust?
YES
Clean or change the Pa-
per Take-Up Roll and/or
Separator Roll.
Is the Paper Take-Up Motor
(M22, M23) turning when the
Start key is pressed?
D
Check the motor for
overload.
D
Change PWB-A
5
NO
(PF-205) or
PWB-A (copier).
Change M22 or M23.
Paper is stationary
at the Vertical
Transport Section.
Is Vertical Transport Drive Motor
M21 turning when the Start key
is pressed?
D
Check the motor for
overload.
D
Change PWB-A
1
NO
(PF-205) or
PWB-A (copier).
Change M21.
2
Are the Vertical Transport Roll-
ers deformed, worn, or dirty with
paper dust?
YES
Clean or change the Ver-
tical Transport Rollers.
3
Does PC17 operate properly?
Using the IC Port Data Check
function, make an input port
check on PWB-A (200) IC1A
PC3 (metric areas) or PWB-A
(MC) IC1A PC3 (inch areas).
NO
Check the PC17 actuator
for operation and, if it op-
erates properly, change
PC17.
4
Does PC22 operate properly?
Using the IC Port Data Check
function, make an input port
check on PWB-A (200) IC1A
PC2 (metric areas) or PWB-A
(MC) IC1A PC2 (inch areas).
NO
Check the PC22 actuator
for operation and, if it op-
erates properly, change
PC22.
5
Does PC21 operate properly?
Using the IC Port Data Check
function, make an input port
check on PWB-A (200) IC1A
PE3 (metric areas) or PWB-A
(MC) IC1A PE3 (inch areas).
NO
Check the PC21 actuator
for operation and, if it op-
erates properly, change
PC21.
Does PC29 operate properly?
Using the IC Port Data Check
YES
Change PWB-A (PF-205)
or PWB-A (copier).
6
function, make an input port
check on PWB-A (200) IC1A
PB3 (metric areas) or PWB-A
(MC) IC1A PB3 (inch areas).
NO
Check the PC29 actuator
for operation and, if it op-
erates properly, change
PC29.