Interleaf EP5000/EP4000 TROUBLESHOOTING
97.04.01
T-47
1156SBT040106A
C06## Optical Malfunctions
*
Code
Description
Detection Timing
C0600
Scanner Motor M2 malfunction
D
When the Scanner is at a position other than
home, Scanner Reference Position Sensor
PC81 does not go from HIGH to LOW even after
the lapse of 20 sec. after the Power Switch has
been turned ON.
D
When the Scanner is at the home position, PC81
does not go from LOW to HIGH even after the
lapse of 5 sec. after the Scanner has started a
scan motion.
D
PC81 does not go from HIGH to LOW even after
the lapse of 20 sec. after the Scanner has started
a scan motion.
C0610
Lens Motor M6 malfunction
The output from Lens Reference Position Sensor
PC90 does not go from HIGH to LOW, or vice
versa, even after the lapse of 15 sec. after M6
has started turning.
C0620
Mirror Motor M7 malfunction
D
The output from Mirror Reference Position Sen-
sor PC86 does not go from HIGH to LOW even
after the lapse of 10 sec. after M7 has started
turning.
D
The output from PC86 does not go from LOW to
HIGH even after the lapse of 3 sec. after M7 has
started turning.
C06F0
SHOME signal failure (Signal does
not go LOW)
D
When the Scanner is at a position other than
home, the SHOME signal does not go HIGH
even after the lapse of 7 sec. after the SCAN sig-
nal has gone LOW.
D
The SHOME signal is HIGH even after the lapse
of 5 sec. after the BASE signal has gone from
LOW to HIGH.
C06F1
SHOME signal failure (Signal does
not go HIGH)
The SHOME signal remains LOW even after the
lapse of 7 sec. after it has gone LOW.
C06F2
BASE signal failure (Signal does
not go LOW)
The BASE signal does not go LOW even after
the lapse of 5 sec. after the SHOME signal has
gone HIGH.
C06F3
BASE signal failure (Signal does
not go HIGH)
The BASE signal remains LOW even after the
lapse of 5 sec. after the SHOME signal has gone
HIGH.
C06F4
TRON signal failure (Signal does
not go LOW)
The TRON signal remains HIGH even after the
lapse of 5 sec. after the BASE signal has gone
LOW.
C06F5
TRON signal failure (Signal does
not go HIGH)
The TRON signal remains LOW even after the
lapse of 5 sec. after it has gone LOW.
C06F6
SCEND signal failure (Signal does
not go LOW)
The SCEND signal remains HIGH even after the
lapse of 5 sec. after the TRON signal has gone
LOW.
C06F7
SCEND signal failure (Signal does
not go HIGH)
The SCEND signal remains LOW even after the
lapse of 5 sec. after it has gone LOW.