Interleaf EP5000/EP4000 TROUBLESHOOTING
97.04.01
T-82
u
C0911
Step
Check Item
Result
Action
Does PC66 operate properly?
Using the IC Port Data Check function,
YES
Replace PWB-A.
1
make an input port check on PWB-A
(IC3A) APB2.
NO
Replace PC66 or PWB-M2.
u
C0912, C0913
Step
Check Item
Result
Action
Does PC70 operate properly?
Using the IC Port Data Check function,
YES
Replace PWB-A.
1
make an input port check on PWB-A
(IC3A) BPA3.
NO
Replace PC70 or PWB-M2.
u
C0916
Step
Check Item
Result
Action
1
Remove the Right Door, lift up the Lock
Lever with a flat-blade screwdriver to
unlock and slide out the 2nd Drawer.
–
2
Is the Lock Release Spring installed
properly?
NO
Reinstall or change.
3
Are the Lock Lever and Torsion Spring
installed properly?
NO
Reinstall or change.