Interleaf EP5000/EP4000 TROUBLESHOOTING
97.04.01
T-107
1156SBT0404A
4-4. Miscellaneous
D
The message “Stabilizing Image Controller not run.” appears on the Touch Panel.
Condition
Detection Timing
T/C is less than 4% when an F5 operation is
run (initial adjustment).
D
Memory clear
D
“PC Drum” of “Port/Option” counter is cleared.
D
AIDC Sensor Board PWB-G develops a malfunc-
tion.
<Procedure>
Step
Check Item
Result
Action
1
Is “ATDC Current Level” of “Level His-
tory” available from Tech. Rep. mode
YES
Run the auxiliary toner replenishing
cycle and then an F5 operation.
less than 4%?
NO
Run an F5 operation again.