changed and saved (default 48, 28-200 optional)
Click on the "Save" button to display "Parameter saved successfully" message, set to take effect.
6) Video output
Output format:
S version: 1080P60, 1080P50, 1080P30, 1080P25, 1080I60, 1080I50, 720P60, 720P50, 720P30, 720P25,
1080P59.94, 1080I59.94, 720P59.94
M version: 1080P30, 1080P25, 1080I60, 1080I50, 720P60, 720P50
Click on the "Save" button, it will be valid when display "Save successful".
4.2.6 Network Configuration
1) Network port
Data port:
set the data port, the device will restart automatically after changed (default 3000, 0-65535 optional)
Web Port
: Set Web port, the device will restart automatically after changed (default is 80, 0-65535 is optional)
Onvif Port
: Set Onvif port, the device will restart automatically after changed (default 2000, 0-65535 optional)
Soap Port
: Set Soap port (default 1936, 0-65535 optional)
RTMP Port:
Set RTMP port (default 1935, 0-65535 optional)
RTSP Port
: Set RTSP port, the device will restart automatically after changed (default 554, 0-65535 optional).
Visca Port
: Set Visca port, the device will restart automatically after changed (default 1259,0-65535 optional).
Click on the "Save" button, it will be valid when display "Save successful".
RTSP Obtaining method: rtsp: // device IP address: 554 / live / av0 (av0 main stream; av1 secondary stream)
RTMP Obtaining method: rtmp: // device IP address: 1935 / live / av0 (av0 main stream; av1 secondary stream)
2) Ethernet parameters
DHCP:
Enable or disable obtain IP automatically can be set. Save changes and reboot the device to takes effect
(default: OFF)
IP Address:
Set the IP address, save changes and reboot the device to takes effect (default 192.168.5.163). Note:
This IP address is the same with the one used to login Web page.
Subnet Mask:
Set the subnet mask (default 255.255.5.0).
Default Gateway
: Set the default gateway (default 0.0.0.0).
Physical Address
: Set the physical address (the parameter is read-only but can not be modified).
Click on the "Save" button, it will be valid when display "Save successful". (Note: To prevent IP conflicts When
modify)
3) DNS parameters
Preferred DNS server: set the preferred DNS server. (Default 0.0.0.0).
Alternate DNS server: Alternate DNS server settings. (Default 0.0.0.0).
Click on the "Save" button, it will be valid when display "Save successful".
4) GB28181
Switch: set whether open GB28181, can check
Time Synchronization: whether synchronization time is set, you can check
Stream Type: stream type setting (the default main stream, secondary stream optional)
Sign effective time (in seconds): 3600 Range 5-65535
Heartbeat time (seconds): 60 Range 1-65535
Register ID: 34020000001320000001
Register User name: IPC
Register Password: 12345678
Equipment ownership: Users can add their own
Administrative regions: Users can add their own