TROUBLE SHOOTING CHECKLIST
SYMPTOM
CHECK
※
The unit does not run & the controller or fans do not
work or the lights are off
※
Make sure the unit is plugged in
※
Check for a tripped circuit breaker
※
Unit does not run, but the controller is on
※
Check the temperature setting on the controller
※
Unplug the unit, wait two hours and plug it in. If you hear it running, a problem is causing the compressor to
overheat
※
Check if the evaporator fan is running
※
Listen if the compressor ever runs. If not the compressor might be faulty
※
Unit is not cold enough
※
Check the temperature setting
※
Assure that there is enough room for airflow in the fridge.
※
Check for airflow restrictions in front and at the back of the grille.
※
Clean the condenser coils
※
Check the door seal
※
Unit is too cold
※
Check the temperature setting
※
Unit is noisy
※
Hissing and popping sounds are normal.
※
Check that the fridge is level
※
Unit runs continuously
※
Check the door seals
※
Clean Condensor
※
In the event of a breakdown
※
Disconnect the fridge from the power supply. Contact your supplier for advice.
※
Compressor does not run and red light emmitting
diode flashes
※
i - Once every 4 Seconds
※
Check wiring thickness as per manual. Check for loose connections in plugs or leads.
※
Check for low battery and re-charge with fridge disconnected from battery
※
ii. Twice every 4 Sec
※
Disconnect fan at F. If problem goes away, replace fan motor. If persists contact your Minus 40 Dealer/
Agent
※
iII. Three times every 4 Sec
※
Switch fridge off for 15 minutes to allow differential pressure to equalize in the Refrigeration system.
※
Restart fridge.
※
i. Four times every 4Sec
※
Check that fan working
※
Check that ambient temperature does not exceed 55°C. Pre-cool the unit before loading