Thank you for purchasing this power protection product.  It has been designed
and manufactured to provide many years of trouble free service.  Please read
this manual before installing your Enspire Series UPS, models EN350, EN550
as it provides important information that should be followed during the installa-
tion and the maintenance of the UPS system allowing you to correctly set up
your system for the maximum safety and performance.  Included is informa-
tion on customer support and factory service, if it is required.  If you experi-
ence a problem with the UPS system please refer to the Troubleshooting guide
in this manual to correct the problem or collect enough information so that the
Technical Support Department can assist you.

CAUTION!

  The maximum ambient operating temperature for this UPS series

is 40°C (“0 ~ 40°C” for Ambient Operation).

The external vents and openings on the UPS are provided for ventilation.
To ensure reliable operation of the UPS and to protect the UPS from over-
heating, these vents and openings must not be blocked or covered. Do not
insert any object into any of the vents or openings that may hinder the ve-
ntilation.

Install the UPS system in a well ventilated area, away from excess moistu-
re, heat, dust, flammable gas or explosives.

Leave adequate space (at least 20cm) around all sides of the UPS system
for proper ventilation.

 Before usage, you must allow the UPS system to adjust to room temper-

ature (20°C~25°C or 68°F~77°F) for at least one hour to avoid moisture
condensing inside the UPS.

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS !

CONSIGNES DE SÉCURITÉ IMPORTANTES

SAUVEGARDEZ CES CONSIGNES!

Chapter 1:  Introduction

WARNING:

  

Risk of Electrical Shock.  Hazardous live parts inside these

power supplies are energized from the battery even when the AC input is
disconnected.

CAUTION!  

To de-energize the outputs of the UPS:

1.

If the UPS is on press and release the On/Off Button.

2.

Disconnect the UPS from the AC wall outlet.

3.

To completely de-energize the UPS, disconnect the battery.

CAUTION!

 

 To reduce the risk of electrical shock in conditions where the

load equipment grounding cannot be verified, disconnect the UPS from the
AC wall outlet before installing a computer interface cable.  Reconnect the
power cord only after all signaling connections are made.

CAUTION!  

Connect the UPS to a two pole, three wire, grounded, utility

power AC wall outlet.  The receptacle must be connected to the appropriate
branch protection (circuit breaker or fuse).  Connection to any other type of
receptacle may result in a shock hazard and violate local electrical codes.  Do
not use extension cords, adapter plugs, or surge strips.

CAUTION!  

To reduce the risk of electrical shock with the installation of this

UPS equipment and the connected equipment, the user must ensure that the
combined sum of the AC leakage current does not exceed 3.5mA.

WARNING:

  

This Uninterruptible Power Supply contains potentially hazard-

ous voltages.  Do not attempt to disassemble the UPS beyond the battery
replacement procedure.  This UPS contains no user serviceable parts.  Re-
pairs and battery replacement must be performed by

 QUALIFIED SERVICE

PERSONNEL ONLY.

CAUTION!

  To reduce the risk of fire, connect only to a utility power circuit

provided with 20 amperes maximum branch circuit over-current protection in
accordance with the National Electric Code, ANSI/NFPA 70.

WARNING:  Qualified Service Personnel ONLY 

must perform the Installa-

tion and Servicing of these UPS systems.  MINUTEMAN accepts no liabilities
and is not limited to: injury to the Service Personnel, or damages to; the UPS,
or the connected equipment caused by the incorrect installation or servicing
of the UPS system.

Veuillez lire ce manuel avant l'installation de l'onduleur modèles EN350, EN550.
Il contient de l'information importante qui doit être respectée au cours de
l'installation et de l'entretien de l'onduleur et des batteries. Cette information
vous permettra de correctement installer le système pour atteindre son
rendement maximum en toute sécurité.

CAUTION!

  This UPS series is 

ONLY

 intended to be installed in an indoor

temperature controlled environment that is free of conductive contaminants.
This UPS series is not intended for use in a computer room as defined in the
Standard for the Protection of Electronic Computer/Data Processing Equip-
ment ANSI/NFPA 75.

Summary of Contents for EN350

Page 1: ...User s Manual Para Systems Inc 1455 LeMay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000495 R1 Enspire Series UPS EN350 EN550 ...

Page 2: ...trols and Indicators 6 3 Installation 8 4 Operation 11 5 Troubleshooting 14 6 Replacing the Battery 15 7 Obtaining Service 18 8 Specifications 19 9 Limited Product Warranty 21 A1 Declaration of Conformity 22 Table Of Contents ...

Page 3: ...ock in conditions where the load equipment grounding cannot be verified disconnect the UPS from the AC wall outlet before installing a computer interface cable Reconnect the power cord only after all signaling connections are made CAUTION Connect the UPS to a two pole three wire grounded utility power AC wall outlet The receptacle must be connected to the appropriate branch protection circuit brea...

Page 4: ...interference to radio and television reception If this equip ment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the computer with respect to the receiver Move the computer away from the rece...

Page 5: ... Once the UPS reaches the LBW Low Battery Warning threshold the alarm will start beep ing The alarm cannot be silenced during the LBW alarm Once the UPS transfers back to the AC normal mode the alarm will reset back to the default setting Output Power Receptacles NEMA 5 15P W 4 ft cord Model Input Power Cord 4 NEMA 5 15R Battery Backup Surge 4 NEMA 5 15R Surge Only 1 Alarm Silencer Button Silences...

Page 6: ...ked on or damaged Typical battery life is 3 to 5 years Envi ronmental factors do affect battery life High temperatures poor utility power and frequent short duration discharges have a negative impact on battery life This UPS series is not intended for use in a computer room as defined in the Standard for the Protection of Electronic Computer Data Processing Equipment ANSI NFPA 75 Operating Tempera...

Page 7: ... the other end of the USB cable to the device that will be monitoring controlling the UPS and then follow the prompts on the screen NOTE When using the UPS s USB port with Windows XP 7 8 or 10 the Power Options in the Control Panel may need to be configured Connecting to the Communications Port is optional The UPS works properly with out this connection SYSTEM OVERVIEW This Standby UPS protects co...

Page 8: ...m will stop the On Battery LED will turn off and the AC normal LED will turn on LOW BATTERY WARNING When the batteries reach the predetermined level the Warning Fault LED will turn on and the alarm will sound two beeps every five seconds The audible alarm cannot be silenced during the LBW alarm This information is to inform the user that there is approximately two minutes of runtime remaining befo...

Page 9: ...RSONNEL ONLY CAUTION Do not open or mutilate batteries Released electrolyte is harmful to the skin and eyes and may be toxic QUALIFIED SERVICE PERSONNEL ONLY CAUTION Do not dispose of batteries in a fire The batteries may explode The batteries in this UPS are recyclable Dispose of the batteries properly The batteries contain lead and pose a hazard to the environment and human health if not dispose...

Page 10: ... with the UPS on the load will not be backed up To hot swap the battery module start with step number 6 1 Turn off the equipment that is plugged into the output of the UPS 2 Turn off the UPS 3 Unplug the UPS s AC power cord from the AC wall outlet 4 Unplug the equipment from the output receptacles of the UPS 5 Unplug the computer interface cable from the side panel of the UPS NOTE No tools are req...

Page 11: ...t It is important to pack the unit properly in order to avoid damage in transit Never use Styrofoam beads for a packing material a Include a letter with your name address day time phone number RMA number a copy of your original sales receipt and a brief desc ription of the problem 5 Mark the RMA on the outside of all packages The factory cannot accept any package without the RMA marked on the outs...

Page 12: ...ystems only covers faulty parts Para Systems products that are depot repaired or replaced pursuant to this warranty shall only be warranted for the unexpired portion of the warranty applying to the original product This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase The warranty shall be void if a the equipment is damaged by...

Page 13: ... C62 41 Category A1 UL1778 CSA 22 2 no 107 3 14 R 2014 FCC Class B Manufacturer s Name Para Systems Inc MINUTEMAN UPS Manufacturer sAddress 1455 LeMay Drive Carrollton Texas 75007 USA Type of Equipment Uninterruptible Power Supplies UPS Model No EN350 EN550 I hereby declare that the equipment specified above conforms to the above Directive s Place Carrollton Texas USA Date July 1 2016 Robert Calho...

Page 14: ...25 24 Notes Notes ...

Reviews: