Para Systems, Inc. (Para Systems) warrants this equipment, when properly applied and
operated within specified conditions, against faulty materials (excluding the batteries) or
workmanship for a period of three years from the date of purchase.  Para Systems Inc.
(Para Systems) warrants the batteries for a period of two years from the date of pur-
chase.  For equipment sites within the United States and Canada, this warranty covers
depot repair or replacement of defective equipment at the discretion of Para Systems.
Depot repair will be from the nearest authorized service center.  The customer pays for
shipping the product to Para Systems.  Para Systems pays ground freight to ship the
product back to the customer.  Replacement parts and warranty labor will be borne by
Para Systems.  For equipment located outside of the United States and Canada, Para
Systems only covers faulty parts.  Para Systems products that are depot repaired or
replaced pursuant to this warranty shall only be warranted for the unexpired portion of
the warranty applying to the original product.  This warranty applies only to the original
purchaser who must have properly registered the product within 10 days of purchase.

The warranty shall be void if (a) the equipment is damaged by the customer, is improp-
erly used, is subjected to an adverse operating environment, or is operated outside the
limits of its electrical specifications; (b) the equipment is repaired or modified by anyone
other than Para Systems or Para Systems approved personnel; or (c) has been used in
a manner contrary to the product’s User's Manual or other written instructions.

Any technical advice furnished before or after delivery in regard to use or application of
Para Systems’ equipment is furnished without charge and on the basis that it represents
Para Systems’ best judgment under the circumstances, but it is used at the recipient’s
sole risk.

EXCEPT AS PROVIDED HEREIN, PARA SYSTEMS MAKES NO WARRANTIES, EX-
PRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT-
NESS FOR A PARTICULAR PURPOSE.  Some states do not permit limitation of implied
warranties; therefore, the aforesaid limitation(s) may not apply to the purchaser.

EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL PARA SYSTEMS BE LIABLE
FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES
ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSI-
BILITY OF SUCH DAMAGE.  Specifically, Para Systems is not liable for any costs, such
as; labor for on-site installation, on-site maintenance or on-site service, lost profits or
revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, cost
of substitutes, claims by third parties, or otherwise.  The sole and exclusive remedy for
breach of any warranty, expressed or implied, concerning Para Systems’ products and
the only obligation of Para Systems hereunder, shall be depot repair or replacement of
defective equipment, components, or parts; or, at Para Systems’ option, refund of the
purchase price or substitution with an equivalent replacement product.  This warranty
gives you specific legal rights and you may also have other rights which vary from state
to state.

No employee, salesman, or agent of Para Systems is authorized to add to or vary the
terms of this warranty.

Chapter 9:  Limited Product Warranty

A1.

DECLARATION OF CONFORMITY

Application of Council Directive(s):  2004/108/EC, 2006/95/EC, cTUVus (for
UL1778)

Standard(s) to which Conformity is declared:  EN61000-3-2, EN61000-3-3,
EN62040-2, IEC61000-2-2 IEC61000-4-2, IEC61000-4-3, IEC61000-4-4,
IEC61000-4-5, IEC61000-4-6, IEC61000-4-8, IEEE C62.41 Category A1,
UL1778, CSA 22.2 no. 107.3-14 / R: 2014, FCC Class B

Manufacturer’s Name:  Para Systems, Inc.  (MINUTEMAN UPS)

Manufacturer’s Address: 1455 LeMay Drive

Carrollton, Texas 75007  USA

Type of Equipment:  Uninterruptible Power Supplies (UPS)

  Model No:   ETR550LCD, ETR700LCD, ETR1000LCD,

       ETR1500LCD

I hereby declare that the equipment specified above conforms to the above
Directive(s).

Place: Carrollton, Texas, USA

 Date: June 1, 2015

Robert Calhoun
      (Name)

Manager Engineering
        (Position)

Year of Manufacture:   Beginning June 1, 2015

Summary of Contents for ETR1000LCD

Page 1: ...User s Manual Entrust LCD Series UPS Para Systems Inc 1455 LeMay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000493 R2x...

Page 2: ...rols and Indicators 6 3 Installation 9 4 Operation 12 5 Troubleshooting 15 6 Replacing the Battery 16 7 Obtaining Service 19 8 Specifications 20 9 Limited Product Warranty 22 A1 Declaration of Conform...

Page 3: ...the battery CAUTION To reduce the risk of electrical shock in conditions where the load equipment grounding cannot be verified disconnect the UPS from the AC wall outlet before installing a computer...

Page 4: ...to correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the computer with respect to the receiver Move the computer away from the receiver Plug th...

Page 5: ...UPS will sound a constant alarm to indicate that there is an Overload condi tion Battery Capacity Bar Graph Displays the amount of Battery Ca pacity available in the AC and Battery mode as 20 40 60 80...

Page 6: ...cement and all the cautions before installing the UPS Place the UPS in the final desired location and complete the rest of the installation procedure These UPSs are shipped with the internal batteries...

Page 7: ...the UPS Use only the interface cable that come with these UPSs The USB communications protocol is HID The HID USB driver comes standard in the Windows OS Simply connect the USB cable to the USB commun...

Page 8: ...release TEST BUTTON To perform a ten second user invoked battery test With the UPS in theAC normal mode press and hold the On Off Test Button until the alarm sounds four beeps and then release During...

Page 9: ...yed on the LCD screen the alarm will sound continu ously and the output will be turned off The fault condition in some instances may be cleared by turning the UPS off and then on If the fault conditio...

Page 10: ...re attempting to ser vice the batteries Typical battery life is 3 to 5 years Environmental factors do affect battery life High temperatures poor utility power and frequent short duration discharges ha...

Page 11: ...f the model information about your unit d The serial number of your unit e Any information on the failure including LEDs that may be illuminated or error codes displayed f A description of the protect...

Page 12: ...hutdown Immediately Chapter 8 Specifications BATTERY SYSTEM Typical Recharge Time Typical Battery Life 3 to 5 years Environmental factors do affect battery life High temperatures poor utility power an...

Page 13: ...RANTIES EX PRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITYAND FIT NESS FORAPARTICULAR PURPOSE Some states do not permit limitation of implied warranties therefore the aforesaid limitation s...

Page 14: ...25 24 Notes Notes...

Reviews: