4
OPERATING INSTRUCTIONS
BEFORE STATING, FAMILIARIZE YOURSELF WITHTHE MACHINE AND ITS CONTROLS
(SEE “MACHINE OVERVIEW” & CONTROL PANEL DIAGRAMS)
1. Filling: Fill the solution tank with the desired amount of water and add liquid
cleaning solution to the proper dilution ratio. DO NOT USE powdered cleaning
chemicals. Powders are unlikely to dissolve thoroughly, resulting in clogging the
in-line solution filter. This can reduce or stop water flow to the brush.
2. Close lid.
3. Turn on machine by pressing the main power switch (10).
4. Lower brush assembly.
-
To lower the brush, first push the pedal (7) slightly outward on the machine (unlock it),
and then release it slowly.
-
To lift the brush, press the pedal (7) down until lift mechanism engages.
5. Turn on brush (11).
6. Adjust solution control feed lever (4).
7. Turn on vacuum switch (12).
8. Lower squeegee assembly by lowering handle (1).
After Use:
1. Turn off solution feed (4).
2. Switch off brush (11) and raise (7).
3. Raise squeegee assembly (1).
4. Turn off vacuum motor (12).
Solution and recovery tanks should be emptied after every use.
MAINTENANCE:
Daily
1. Clean float assembly & squeegee blades. Vac filter.
Monthly 1. Check wear on squeegee blades.
2. Grease front wheels.
3. Grease pivot points on brush motor assembly.
Every 500 hours check condition of carbon brushes on vacuum motor and brush drive motor.