10
.
4. Connect the new battery in place of the old one, ensuring that black wire is connected to the
negative (-) terminal and the red wire is connected to the positive (+) terminal. ( the Pro 1400
connectors are keyed) Small sparks at the battery connection are normal.
5. Place the new battery in the case taking care not to pinch any wires.
6. Slide the battery door back into its slot and replace the retaining screw.
7. Dispose of the battery properly at an appropriate recycling facility or return it to the supplier in
the packing material for the new battery. See new battery instructions for more info.
B
ATTERY
R
EPLACEMENT
P
ROCEDURE
PLEASE READ THE CAUTIONS SECTION BEFORE ATTMPTING TO REPLACE
THE BATTERIES
1. Lay the unit on its side or bring to the edge of a table.
Remove the retaining screw holding the
battery door in place and slide the door towards the
bottom of the unit.
2. Gently pull out the battery by grasping the battery removal tab
3. Disconnect the two wires (disconnect the connector on the 1400 va unit) connecting the battery
to the UPS. Pull back straight on the connector while wiggling the connector from side to side.